Instructions for the installer, Final operations, 4 regulation of primary air – Smeg CSA19ID-6 User Manual

Page 11: 1 adjustment of minimum for natural gas, 2 adjustment of minimum for lpg

Advertising
background image

Instructions for the installer

3.4 Regulation of primary air

Referred to distance “X” in mm.

Models CSA19 / CSA196 / CSA20


Burner

NG

1.00 kPa

LPG

2.75 kPa

Auxiliary

3.0

2.5

Semi rapid

3.0

2.0

Rapid

3.0

2.0

Wok

4.0

2.5

Fish burner (*)

4.0

4.0

(*) Models CSA19 / CSA196



4. FINAL OPERATIONS

Having carried out the above adjustments, reassemble the appliance
following, backwards, the instructions in paragraph “3.1 Raising of the
hob”.


4.1 Adjustment of minimum for natural gas

Light the burner and take it to the minimum

.

Remove the gas tap knob and turn the
adjustment screw inside or at the side of the tap
shaft (depending on the model) until there is a
regular minimum flame. Replace the knob and
check burner flame stability: (rapidly turning the
knob from maximum to minimum position, the
flame should not go out). Repeat the operation on
all the gas taps.

4.2 Adjustment of minimum for LPG

To regulate the minimum for LPG, completely tighten (clockwise) the
screw inside or next to the gas tap pin (depending on the model).

13

Advertising