Sony PCS-1P User Manual

Page 35

Advertising
background image

2-5

PCS-1/PCS-1P

YES

NO

NO

Turn on power switch on side panel.

Connect them properly.

YES

NO

YES

Is power

turned on when I/O

button of remote controller

is pressed?

Are

communication terminal

and ISDN unit properly

connected?

Does POWER

(amber) lamp light?

SS-03

Communication terminal is defective.

Proceed to “2. The power is not
turned on even if the I/O button of a
remote controller is pressed”.

Connect it properly.

NO

YES

Is ISDN

modular cable properly

connected to IDSN

unit?

ISDN unit or ISDN
line is defective.

NO

YES

Does STATUS

lamp of terminal, to which

ISDN modular cable of ISDN

unit is connected,

light in red?

Communication terminal or
ISDN unit is defective.

NO

YES

Does STATUS

lamp of ISDN unit blink

in green?

3.

The power is not turned on during automatic incoming. (ISDN)

Advertising