2. setting of pcs-1 and hub – Sony PCS-1P User Manual

Page 75

Advertising
background image

4-3

PCS-1/PCS-1P

4-2. Setting of PCS-1 and HUB

The initial setting of the PCS-1 is Auto.
In the Auto setting of the PCS-1, 10/100 can be selected automatically, however, Half/Full cannot be selected

automatically. Therefore, if the HUB is set to Full mode, a connection failure or packet loss occurs. The following table
shows an example of connection between the PCS-1 and Catalyst 2950. When the HUB is set to 100FULL or 10FULL,

change the setting of HUB or adjust the PCS-1 setting to HUB. Refer to “2-5. Service Mode” for the setting procedure of
the PCS-1.

Table of connection between PCS-1 and Catalyst 2950

PCS-1 setting

AUTO

100FULL

100HALF

10FULL

10HALF

2950 settting

AUTO

OK

Packet loss

OK

Packet loss

OK

100FULL

Packet loss

OK

Packet loss

Connection failure

Connection failure

100HALF

OK

Packet loss

OK

Connection failure

Connection failure

10FULL

Packet loss

Connection failure

Connection failure

OK

Packet loss

10HALF

OK

Connection failure

Connection failure

Packet loss

OK