Maintenance & troubleshooting, Lamp/maintenance indicators, Maintenance – Sharp XG-V10XU User Manual

Page 70: Oubleshooting, Maintenance indicators

Advertising
background image

E-69

Maintenance &

Tr

oubleshooting

TEMP

LAMP2

LAMP1 POWER

2

1

Lamp/Maintenance Indicators

Problem

• Blocked air intake.

• Clogged air filter.

• Cooling fan breakdown.
• Internal circuit failure.

• Burnt-out lamp.
• Lamp circuit failure.

• Lamp has been used for

over 900 hours.

• The filter cover is open.

• The lens cover* is not

securely installed.

Maintenance Indicator

The internal
temperature is
abnormally high.

TEMPERATURE
WARNING indicator

LAMP REPLACE-
MENT indicator

POWER indicator

The lamp does not
light up.

The lamp requires
replacement.

The POWER
indicator flashes in
red when the
projector is on.

Condition

Possible Solution

• Relocate the projector to an area with

proper ventilation.

• Replace the filter.

(See page 73.)

• Take the projector to your nearest

Authorized Sharp Industrial LCD Products
Dealer or Service Center for repair.

• Carefully replace the lamp. (See pages 71

and 72.)

• Take the projector to your nearest

Authorized Sharp Industrial LCD Products
Dealer or Service Center for repair.

• Securely install the filter cover.

• Securely install the lens cover.

Maintenance Indicators

• The warning lights on the projector indicate problems

inside the projector.

• There are three warning lights: a TEMPERATURE

WARNING indicator that warns you when the projector
is too hot, and two LAMP REPLACEMENT indicators
that warn you when to change a lamp.

• If a problem occurs, either the TEMPERATURE

WARNING indicator or the LAMP REPLACEMENT
indicators will light up red. After turning off the power,
follow the procedures given below.

LAMP 2
REPLACEMENT
indicator

TEMPERATURE
WARNING
indicator

LAMP 1
REPLACEMENT
indicator

POWER
indicator

• If the TEMPERATURE WARNING indicator lights up, follow the above possible solutions and then wait until the projector has

cooled down completely before turning the power back on. (At least 5 minutes.)

• If the power is turned off and then turned on again, as during a brief rest, the LAMP REPLACEMENT indicators may be

triggered, preventing the power from going on. Should this occur, take the power cord out of the wall outlet and put it back
in again.

* The lens cover is as shown below.

Lens cover

Advertising