6 telephone tests – Siemens OPTIPOINT 500 User Manual

Page 40

Advertising
background image

Startup

Nur für den internen Gebrauch

P31003-E8400-A100-3-7620

3-4

Service Manual

Telephone Tests

3.6

Telephone Tests

Accessing the Telephone Test

The telephone test is started by pressing the "service key" and entering the "code number".

Tests run for approx. 10 s. These are followed by a timeout.

Tests can be stopped at any time by pressing the pound key

.

optiPoint 500 Models with Display (economy, basic, standard and advance)

You can browse and display individual tests in the Service menu.

Display individual call numbers

Activate LEDs and calls.

Display showing if power supply is sufficient

if sufficient power is being supplied, a light grey pixel pattern is visible

Code

number

Menu text

Action after pressing OK

91

LED

Start the LED test

92

Screen

Start the screen tests

93

Keys

Start the key test

94

Audio

Go to the audio test/submenu

941 Speaker

Test the speaker volume (7 levels)

942 Handset

Test the handset volume (7 levels)

943 Ringer volume

Change the ringer volume (7 levels)

944 Ringer pitch

Change the ringer pitch (7 levels)

945 Alerting tone

Change the volume of the alerting tone (7 levels)

946 Speakerphone mode

Handsfree function (3 levels):
normal, loud, noisy room

940 Back

Return to the audio test

95

Asset ID

Display the asset ID

96

Software version

Display the telephone SW version

97

Feeding range

Start the feeding range test

90

Back

Return to the telephone test

Table 3-1

Telephone test for HiPath 4000/Hicom 300 H

Advertising