Siemens OPTIPOINT 500 User Manual
Page 87
P31003-E8400-A100-3-7620
Service Manual
7-23
Nur für den internen Gebrauch
IP Adapter
Administration via optiPoint 500
Figure 7-5
Faults shown on optiPoint display
Once a fault occurs, press any key on the terminal to open the optiPoint IPadapter administra-
tion menu. You can resolve the fault there by modifying the appropriate settings.
If a parameter is invalid or not set correctly, the following error messages are also displayed for
the configuration setting:
’CFG error Oxnnnn’
Example:
If an invalid Partner_IP address is entered or if the partner IP address is not set, the following
error code appears: ’0x1000’ (see figure below)
NO DHCP response
Press any key? >
Ping to Gateway failed
Press any key? >
Ping to Partner failed
Press any key? >
highest priority
lowest priority
Generic socket error
Press any key? >
TC Login Error
Press any key? >
Error connecting partner
Press any key? >
Unknown Error
Press any key? >