Siemens OPTIPOINT 500 User Manual

Page 68

Advertising
background image

IP Adapter

Nur für den internen Gebrauch

P31003-E8400-A100-3-7620

7-4

Service Manual

Connection to the System

7.3

Connection to the System

Figure 7-3

Overview: connecting an optiPoint IPadapter to the system

Connect the optiPoint IPadapter to the Hicom system in the following sequence (please also
note the diagram "Electrical connection of the optiPoint IPadapter"):

1.

First of all, connect the U

P0/E

port of the IPadapter to the Hicom system (SLMO board).

Use the cable supplied with RJ-11 Mini-Western connectors (point 1).

2.

Connect the IPadapter to the LAN network. Use the LAN network cable (max. 3 m) sup-
plied for this (cable features 3 RJ-45 Mini-Western connector (point 2)).

The optiPoint IPadapter can be operated as a desktop unit or can be mounted on the wall with
a screw. The wall attachment can be found on the back of the IPadapter (point 3).

Figure 7-4

Electrical connection of the optiPoint IPadapter

PIN assignments on the IPadapter

Connector/ jack

Pin 1

Pin 2

Pin 3

Pin 4

Pin 5

Pin 6

Pin 7

Pin 8

U

P0/E

RJ11

NC

DC-

a(U

P0/E

) b(U

P0/E

)

DC+

NC

LAN

RJ 45

TDX+

TCD-

RXD+

NC

NC

RXD:

NC

NC

Table 7-1

Pin assignment

1

2

Hicom/

HiPath
(SLMO

board)

LAN - I/F

10 Base T

U

P0/E

optiPoint

IPadapter

1

2

3

Advertising