1-15-1. Settings for Time Code

To set the TIME CODE, open the P1 page (TCG/TCR SETTING) on the function screen.

When Editing with an Editor (BVE-2000, etc.) Capable of the 1st Edit

When MSW-A2000/A2000P is used by connecting to an editor, set as follows.

Button

Item (Display)

Setting

F1

TCG INT/EXT (TCG)

INT

F2

TCG PRESET/REGEN (TCG)

PRESET

F3

TCG RUN (RUN)

FREE

When Editing with Direct Machine-to-Machine (VTR to VTR)

n
The setup menu ITEM-610: REGEN CONTROL MODE setting data must be set to “AS&IN”.

Button

Item (Display)

Setting

F1

TCG INT/EXT (TCG)

INT

F2

TCG PRESET/REGEN (TCG)

PRESET

F3

TCG RUN (RUN)

REC

1-15-2. VTR Constant Values Settings of Editor

Set the VTR constant values according to the table below when the editor which needs the setting of VTR
constant values is connected. Moreover, the change of VTR constant values are required when the 525/
625 system is switched by setup menu of this unit.

VTR CONSTANT 1

VTR CONSTANT 2

Model

525/625

Data No.

Data No.

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

MSW-A2000

525/60

B0

61

00

96

07

07

03

8A

*

0A

07

FB

00

81

3D

FF

5A

625/50

B1

61

00

7D

07

07

03

8A

*

0A

06

FB

00

83

4B

FF

4B

MSW-A2000P

525/60

B0

61

00

96

07

07

03

8A

*

0A

07

FB

00

81

3D

FF

5A

625/50

B1

61

00

7D

07

07

03

8A

*

0A

06

FB

00

83

4B

FF

4B

*: Set the data of No.8 of the VTR CONSTANT 1 to “0A” for the following editors.

. BVE-900 ROM versions earlier than 1.08
. BVE-600 ROM versions earlier than 1.01

n
When remote-controlling this unit by the editor, set the setup menu ITEM-401: FUNCTION MODE

AFTER CUE-UP to “STOP”.