STEP 5

2.11

OPERATING INSTRUCTIONS

Dismantling equipment
Remote control unit
Unlock the exposure device and then rotate the selector ring from LOCK to CONNECT.

The remote control connector will partially disengage from the exposure device's

locking mechanism.
Completely disengage the remote controls from the exposure device by disengaging the

control cable connector from the source assembly connector. Place the protective cover

over the remote control's connecting plug assembly to exclude dirt and protect the control

cable connector from damage. Roll the remote control conduits loosely for easier handling

and transport.
Reinstall the locking mechanism's protective cover, hold in place and rotate the selector

ring to the LOCK position. Push in the plunger lock and remove the key to lock the

exposure device.
Source guide tubes
Remove the source guide tube attached to the exposure device outlet port by:
1 Rotating the spring-loaded outlet cover 60 degrees in a counter-clockwise direction.
2 Grasp the source guide tube fitting and rotate a quarter of a turn in a clockwise direction.

This action will allow removal of the source guide tube from the outlet port.
3 Simultaneously pull and rotate the spring-loaded outlet port cover a quarter of a turn in a

counter-clockwise direction.
Place the protective covers on the fittings of each source guide tube used to exclude dirt and

protect the swaged fittings. Source guide tubes should be rolled up loosely for easier

handling and transport.
Surveying
After installing the locking mechanism’s protective cover and the outlet port cover, survey

the entire circumference of the exposure device with the survey meter to ensure the source

is fully shielded and properly secured. The survey should not measure more than 200mR/hr

(2mSv/hr) on any surface of the exposure device and should indicate the same measurement

as the initial survey.
Storage
Lock the exposure device and secure it in a clean dry storage area where it cannot

be tampered with or removed by unauthorized personnel. Perform a storage survey

on the surface of the exposure device to verify the dose rate is less than 200mR/hr

(2mSv/hr) and record.
A radioactive material warning notice must be posted on the door or entrance of

the storage area. The door or entrance must be locked to prevent access by

unauthorized personnel.