3.5

DAILY INSPECTION INSTRUCTIONS

Figure 3.4 Sealed source in the exposure mode

Sealed source

Source assembly

Shield

Exposure device

Locking

mechanism

Outlet port

Source

guide tubes

Control cable

Remote

control crank

Exposure mode
When the source assembly reaches the exposure head at the radiographic working position,

the odometer will indicate (in feet and tenths of a foot) the approximate distance the sealed

source has traveled. (See figure 3.4)
To return the source assembly to the exposure device the crank handle is rotated in the

RETRACT direction (clockwise). When the source assembly is returned to the fully shielded

position within the exposure device, the locking mechanism automatically secures the source

assembly. The automatic securing mechanism will not permit exposure of the source

assembly unless the radiographer pushes the lock slide into the expose position.
The remote controls cannot be disconnected from the source assembly unless the source

assembly is fully retracted into the shielded position in the exposure device.
The system is designed for safe and reliable operation provided the system is properly used

and maintained.