3.3

DAILY INSPECTION INSTRUCTIONS

Figure 3.2 Source assembly in fully shielded position of radiographic exposure device

Sealed source

Source assembly

Shield

Exposure device

Locking

mechanism

Outlet port

Source

guide tubes

Control cable

Remote

control crank

A shielded outlet port cover mechanism permits a secure attachment of source guide tubes

(projection sheaths) without an elevation of radiation levels. The outlet port mechanism will

not allow the source assembly to be projected outside of the exposure device unless a

source guide tube has been properly attached to the outlet port. A three-step connection is

accomplished by completion of the following steps:
1 Pull and rotate the spring-loaded outlet port cover a quarter turn (from a 12 o'clock to a

3 o'clock position) in a clockwise direction. This action moves the protective cover away from

the outlet port to permit attachment of a source guide tube.
2 A bayonet-style fitting of the source guide tube is inserted into the outlet port and

rotated a quarter turn (from a 12 o'clock position to a 9 o'clock position) counter-clockwise.

A complete insertion and counter-clockwise rotation of the source guide tube fitting releases

the lock on an internal shielding rotor of the outlet port.
3 Rotate the spring-loaded cover an additional 60 degrees (from a 3 o'clock position to a

five o'clock position) in a clockwise direction until it stops. This last movement moves the

outlet port shield out of position and aligns a pass-through opening on the rotor with the

‘S’ tube and outlet port while simultaneously securing the source guide tube fitting to the

outlet port.
The design permits attachment of the source guide tubes without an elevation of radiation

intensity at the outlet port, minimizing the radiation exposure to the radiographer's hands.

The sealed source assembly cannot be exposed out of the exposure device unless a positive

connection of the source guide to the device has been accomplished.
The exposure device's locking mechanism provides three main safety features for the

radiographer during radiographic operations.
First, the locking mechanism requires a deliberate action to enable exposure of the source

assembly. This is accomplished by coupling the control cable connector to the source

assembly connector, coupling the remote control connector to the exposure device locking

mechanism and then pushing a lock slide from the SECURED position into the EXPOSE

position. The lock slide must be manually pushed into the EXPOSE position prior to each

radiographic exposure to enable operation of the remote control.