SIGMA 150Ci User Manual

Page 71

Advertising
background image

8.1

INSTRUCTIONS FOR DISPOSAL

By international regulations, radioactive materials that are no longer required must be

transferred to a licensed recipient for final disposition. Iridium-192 source assemblies that

have depleted beyond their useful working life may be returned to authorized recipients

using a source changer authorized for the specific model source assembly.
Authorized recipients will provide any specific conditions to the shipper as required by

regulatory authorities. As a minimum, sources that are transferred for a final disposition

must be within a current leak test and properly secured within an authorized package

before shipment.
Damaged, cropped, modified or contaminated source assemblies may require special

handling and special transport containers. Notify the authorized recipient for specific

instructions in these circumstances.
Depleted Uranium (DU) shielded exposure devices that are removed from service due to

severe damage, worn through ‘S’ tubes or decommissioning reasons must be sent to a

licensed recipient for final disposition. If the Type B transport status of a damaged exposure

device is impaired, the exposure device must be transported without radioactive source

assemblies. DU shielded exposure devices sent for final disposition must be properly

packaged, surveyed, marked and labeled before placement into the transportation system.

Contact AEA Technology QSA, Inc. for assistance in the transfer of DU shielded exposure

device for final disposition.