DIP Switch

DIP Switch Functions

The DM-D500 has two groups of DIP switches.

The functions of the

DIP switches are as follows:

DIP switch 1

(*1)XON/XOFF is effective only when the DM-D500 is connected with a stand alone.

Transmission speed

*Cannot be set to 57,600 or 115,200 when using the IR Series.

DSW1 No.

Function

ON

OFF

Default setting

1-1

Data receive error

Ignored

Displays “?”

OFF

1-2

Hand shaking

XON/XOFF (*1)

DTR/DSR

OFF

1-3

Data length

7 bits

8 bits

OFF

1-4

Parity on or off

Parity

No parity

OFF

1-5

Parity type

Even

Odd

OFF

1-6

Change transmis-

sion speed

See “Transmission speed.”

ON

1-7

OFF

1-8

ON

SW1-6

SW1-7

SW1-8

Transmission speed (bps)

ON

ON

ON

2400

OFF

ON

ON

4800

ON

OFF

ON

9600

OFF

OFF

ON

19200

ON

ON OFF

38400

OFF

ON

OFF

57600*

ON

OFF

OFF

115200*