Engli s h, Dip switch 2 – Seiko Group 201 User Manual

Page 35

Advertising
background image

33

Engli

s

h

DIP switch 2

(*1)The “Y-connection enable” is set when a TM printer with no modular jack for the

DM-D is connected with this product, using one COM port to connect both TM
printer and DM display. In this case, an optional DM-D stand (DP-501) and a
connecting cable are required. In the cases other than above, choose
“Y-connection disable” (default setting).

(*2)This function can select whether or not you perform self test when turning on the

power. See “Self Test” for details.

(*3)When selecting “20 column and 2 line mode,” this product can be used like the

DM-D105/106/205/206. In this case, the graphic display and the original functions
for the DM-D500 cannot be used, but when selecting “256

×

64 dots mode,” they

can be used.

(*4)When setting to “Printer is selected,” data is sent to the TM printer, but is not

displayed on the display. When setting to “Display is selected,” data is displayed
on the display but is not output from the TM printer.
The selection can be changed using <ESC=> command.

(*5)Stay at OFF setting.

Note:

The changes in the DIP switch setting are effective when the power is
turned on again.

The data transmission setting, such as data length, transmission speed,
must be the same on both your computer and printer.

DSW2 No.

Function

ON

OFF

Default setting

2-1

Y-connection (*1)

Enable

Disable

OFF

2-2

Self test selection (*2)

Perform self test

Do not perform

OFF

2-3

20 column and 2 line
mode selection (*3)

20 column and
2 line mode

256 ¥ 64 dots
mode

OFF

2-4

Device selection
default setting

Printer is
selected

Display is
selected

OFF

2-5

Address 0

The display device number
(1-7) corresponds to Address num-
ber 0 to 2.
(All OFF are regarded as no dis-
play number.)

OFF

2-6

Address 1

OFF

2-7

Address 2

OFF

2-8

Reserved (*5)

-

Fixed to OFF

OFF

Advertising