75

C:\WINNT\Profiles\Administrator\Desktop\WORK_08_21\370467401
DVS9000WW\01GB03C01-WW.fm

masterpage:Right

Digital Multi Effects (DME)

Chapter 1

D

V

S-9000 Functions

DVS-9000/9000SF

3-704-674-01 (1)

Values for x-, y- and z-axes (16:9 mode)

Limits of three-dimensional parameters

The following table shows the limits of three-dimensional transformation
parameters.
The three-dimensional parameters of an image change when you use the
trackball or Z-ring to execute a transformation. You can also execute a
transformation by entering parameter values from the numeric keypad control
block.

Detents

The system defines points called detents at regular intervals on the three-
dimensional space. Pressing the [CTR] button in the device control block sets
the current three-dimensional parameter values to the closest detent points.
(For details, see “Three-Dimensional Transformation Operations” in Chapter
11 (Volume 2).)

The following table shows the interval between successive detents for each
transformation operation mode (see page 76).

Operation mode

Limits of three-dimensional transformation parameters

Location XYZ

333.3333 to +333.3333

Rotation, Spin

999.9999 to +999.9999

Axis Location

333.3333 to +333.3333

Location Size

0.0000 to +999.9999

Aspect

0.0000 to +2.0000

Perspective

Perspective (x, y)

33.3333 to +33.3333

Perspective (z)
0.0000 to 999.9999

Skew

3.3333 to +3.3333

Operation mode

Detent interval

Location XYZ

1.00

Rotation, Spin

0.25

Axis Location

1.00

Location Size

0.25

Aspect

1.00

a)

Perspective (x, y)
Perspective (z)

1.00

1.00

a)

Skew

0.10