Minimum clearances, Ventilation, Pecifications – Southbend SLEB/10CCH User Manual

Page 7

Advertising
background image

E

LECTRIC

C

ONVECTION

O

VENS

S

PECIFICATIONS

SPEC

IFICATI

O

NS

MINIMUM CLEARANCES

!

WARNING

There must be adequate clearance between the left side of the ovens and combustible construction.

Minimum Clearance from

Minimum Clearance from

Combustible Construction

Non-Combustible Construction

Back 2"

2"

Right Side

0"

0"

Left Side

0"

0"

Floor 0"

0"

Adequate clearance must be provided in the aisle to allow the doors to open sufficiently to permit the
removal of the racks and for serviceability.

Although no clearance is required behind the motor on the rear of the oven, care must be taken to
provide adequate air circulation to prevent the motor from overheating.

Do not locate the oven adjacent to any high heat or grease-producing piece of equipment, such as a
range top, griddle, fryer, etc., that could allow radiant heat to raise the exterior temperature of the oven
above 130°F (54°C). DO NOT MOUNT ABOVE OTHER COOKING EQUIPMENT.

VENTILATION

NOTICE

Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be
covered by the warranty.

If a ventilation canopy is used, it is recommended that a canopy extend 6" past the appliance and that the
bottom edge be located 6'6" from the floor. Filters should be installed at an angle of 45° or more from the
horizontal. This position prevents dripping grease and facilitates collecting the run-off grease in a drip pan,
unusually installed with a filter.

If an exhaust fan is used, it should be installed at least 2" above the flue opening at the top of the unit. A
strong exhaust fan tends to create a vacuum in the room. Fresh air openings approximately equal to the
fan area will relieve such a vacuum. In case of unsatisfactory performance on any appliance, check the
appliance with the exhaust fan in the “OFF” position. Do this only long enough to check equipment
performance. Then turn the exhaust fan back on and let it run to remove any exhaust that may have
accumulated during the test.