MVDS X-1 User's Guide

Parameter name

Description

Value range

Default value

T

X

R
X

H.Position Offset

Save the offset value for H.Position
setting that you may have configured
from LCD menu.

0 - 100

50

* -

H.Width Offset

Save the offset value for H.Width
setting that you may have configured
from LCD menu.

0 - 100

50

* *

H.Period Offset

Save the offset value for H.Period
setting that you may have configured
from LCD menu.

0 - 100

50

* *

H.Back Porch Offset

Save the offset value for H.Back Porch
setting that you may have configured
from LCD menu.

0 - 100

50

- *

V.Position Offset

Save the offset value for V.Position
setting that you may have configured
from LCD menu.

0 - 100

50

* -

V.Width Offset

Save the offset value for V.Width
setting that you may have configured
from LCD menu.

0 - 100

50

* *

V.Period Offset

Save the offset value for V.Period
setting that you may have configured
from LCD menu.

0 - 100

50

* *

V.Back Porch Offset

Save the offset value for V.Back Porch
setting that you may have configured
from LCD menu.

0 - 100

50

- *

PLLGAIN_H

Specify the PLLGAIN VCO Range.

0 : 8-72MHz
1 : 16-144MHz
2 : 16-144MHz
3 : 24-215MHz

1

* -

PLLGAIN_L

Specify the PLLGAIN Charge Pump
Current.

0 - 7

6

* -

PLLDIV

Specify the ADC PLL Divider ratio.
Usually, equivalent to the value of
H.Period minus one.

0 - 65535

1687

* -

CLPDLY

Specify the Clamp Pulse Delay.

0 - 255

8

* -

CLPDUR

Specify the Clamp Pulse width.

0 - 255

32

* -

HSOPW

Specify a pulse width of ADC HSOUT.

0 - 255

96

* -

SYNC_CTRL

Perform a synchronization control.

0 - 255

64

* -

PHASE_CC

Specify the PHASE for image sampling. 0 - 255

0

* -

Baudrate

Specify a baudrate.

300, 600, 1200, 2400, 4800,
9600, 14400, 19200, 38400,
57600, 115200

19200

* *

Bit length

Specify a bit length.

8, 7

8

* *

Stop bit

Specify a stop bit.

1, 2

1

* *

Parity

Specify a parity check method.

None, Odd, Even

None

* *

Flow control

Specify a flow control method.

None, XON/XOFF, RTS/CTS

None

* *

Data Timeout

Specify a serial input timeout by
millisecond.

50-1000

100

* *

Buffer level

Specify the number of buffer for
retransmission.

16 - 64

64

* *

Node List Method

Specify a node search method.

Dynamic, Static

Dynamic

* *

Static Node 0 - 7

Specify an IP address for node when
Node List Method is set to Static.

IP Address

0.0.0.0

* *