Caution, Superior, Wiring diagrams – Superior SSBV-3530CNM User Manual

Page 12: Figure 20 - millivolt wiring diagram, Distributor. figure 19, Figure 18, Igniter rod hood, Figure 21, Schematic representation only

Advertising
background image

1

Electronic Appliance Checkout

To light the burner, refer to the lighting instruc-

tions on Pages 18 & 19. Ensure the igniter

lights the pilot. The pilot flame should engulf

the flame sensor as shown in Figure 19.

With proper care and maintenance, your appli-

ance will provide many years of enjoyment. If

you should experience any problem, first refer

to the troubleshooting guide in this manual.

If problem persists, contact your

Superior

distributor.

Figure 19

/8" to 1/"

(9 -1 mm)

Ground

Electrode

Flame Rod

Hot Surface

Igniter

Proper Flame

Adjustment

Pilot

Nozzels

ELECTRONIC PILOT ASSEMBLY

Proper Pilot Flame Appearance

Figure 17

Thermocouple

Thermopile

Pilot

Nozzels

SIT MILLIVOLT PILOT ASSEMBLY

/8" Min.

(9 mm)

Igniter Rod

Hood

Proper Pilot Flame Appearance

Figure 18

Proper Pilot Flame Appearance

Thermocouple

Thermopile

Pilot

Nozzels

/8" Min.

(9 mm)

1/8" Min.

( mm)

Igniter Rod

Hood

HONEYWELL MILLIVOLT PILOT ASSEMBLY

WIRING DIAGRAMS

Wiring diagrams are provided here for reference purposes only. This information is also provided

on schematics attached directly to the appliance on a pullout panel located within the control

compartment.

CAUTION

Label all wires prior to disconnection when servicing controls. Wiring

errors can cause improper and dangerous appliance operation.

• Schematic Representation Only
• If any of the original wire as supplied must

be replaced, it must be replaced with Type

AWM105 C - 18 gage wire.

u

Optional Kits - OFF/ON wall switch or remote

control receiver.

v

Appliance mounted OFF / ON Switch

Figure 20 - Millivolt Wiring Diagram

Field Wired

Factory

Wired

BK = BLACK

WT = WHITE

u

v

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Figure 21

Electronic Wiring Diagram (Honeywell) Showing Blower Wiring

for Optional FBK-100 & FBK-200 Kits

1. If any of the original wire as supplied must be

replaced, it must be replaced withType AWM

105°C - 18 GA. wire.

1.

2. 120V , 60Hz – Less than 3 amps.

BK

T ransf.

120 V.

24 V

BL

Electronic Wiring Diagram (Honeywell)

R

BL

W

Gas Va lve

B

R

IGNITER

PILOT

ASSEMBLY

BK

BK

BK

*ON/OFF Switch (Integral

with Gas Va lve )

*Leave the ON/OFF switch, which

is integral with the gas valve,

in the ON position.

SPILL SWITCH

(high limit disc)

WT

G

J-BOX

OPTIONAL

BLOWER

Field Wired

Factory

Wired

Schematic Representation Only

u

Burner OFF/ON Switch on Valve Bracket

(optional switch on some models).

v

Optional Control Switches - OFF/ON wall switch

or remote control receiver.

1. If any of the original wire as supplied must be replaced,

1.

it must be replaced with Type AWM 105

°C – 18 GA. wire.

2. 120V, 60Hz – Less than 3 amps.

Wiring Diagram

Showing the Blower Wiring

for the Optional FBK-100 Kit

Factory Wired

Field Wired

Schematic Representation Only

Junction Box

Tab Intact

Tab

Broken

Plug blower

into this

receptacle

n

e

e

r

G

-

d

n

u

o

r

G

*Optional Accessory Switch

Optional

Blower

Ground

e

ti

h

W

-

l

a

rt

u

e

N

120 VAC - Black

Green

Ground

Screw

White

Green

Neutral

Side of

Receptacle

Hot

Side of

Receptacle

Red

Black

*J-BOX WIRING FOR

OPTIONAL (BLOWER

CONTROL) ACCESSORY

SWITCH

j-Box Wiring Diagram

u

v

TH

TP

TH

TP

WT

BK

BK

BK

Spill Switch

Advertising