LIGHTING INSTRUCTIONS – HONEYWELL AND SIT MILLIVOLT GAS VALVE

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION

MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INjURY OR LOSS OF LIFE.

FOR YOUR SAFETY READ BEFORE LIGHTING

A. This appliance has a pilot which must be lighted with a piezo

igniter. When lighting the pilot, follow these instructions

exactly.

B. BEFORE OPERATING smell all around the appliance area for

gas. Be sure to smell next to the floor because some gas is

heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Extinguish any open flame.
• Open windows.
• Do not light any appliance.
• Do not touch any electrical switches.

TO TURN OFF GAS TO APPLIANCE

1. Turn remote wall switch “OFF.” The pilot will remain lit for

normal service.

. For complete shutdown, turn remote wall switch to “OFF.”

. Access the lower control compartment.

4. Depress gas control knob slightly and turn clockwise

to “OFF.” Do not force.

5. Close lower control compartment.

LIGHTING INSTRUCTIONS

1. STOP! Read the safety information above on this Page.

. Access the lower control compartment.

. Turn remote wall switch to “OFF.”

4. Verify main line shut-off valve is open.

5. Push in gas control knob slightly and turn clockwise

to “OFF.”

• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s

phone.

• If your gas supplier cannot be reached, call the fire depart-

ment.

C. Use only your hand to push in or turn the gas control knob.

Never use tools. If the knob will not push in or turn by hand,

do not try to repair it, call a qualified service technician. Force

or attempted repair may result in a fire or an explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect the

appliance and to replace any part of the control system and

any gas control which has been under water.

Note: Knob cannot be turned from “PILOT” to “OFF”

unless the knob is pushed in slightly. Do not force.

HONEYWELL

MILLIVOLT

GAS VALVE

SIT

MILLIVOLT

GAS VALVE

SIT

MILLIVOLT PILOT

HONEYWELL

MILLIVOLT PILOT

ON

OFF

PI

LO

T

L

O

HI

HI

L O W

HT

PT

HT

PT

PILO

T

PIL

OT

ON

ti

OFF

OUT

IN

IGNITER

IGNITER

6. Wait five (5) minutes to clear out any gas. If you then smell gas,

STOP! Follow “B” in the safety information above on this Page. If you

do not smell gas, go to the next step.

7. Push in gas control knob slightly and turn counterclockwise

to “PILOT.”

8. Push in control knob all the way and hold in.

Immediately light the pilot by triggering the

spark igniter (pushing the button) until pilot

lights. Continue to hold the control knob in

for about 1 minutes after the pilot is lit.

Release knob and it will pop back up. Pilot

should remain lit. If it goes out, repeat steps 5

through 8.

If knob does not pop up when released,

stop and immediately call your service

technician or gas supplier.

If pilot will not stay lit after several tries,

turn the control knob to “OFF” and call

your service technician or gas supplier.

9. Turn gas control knob counterclockwise

to “ON.”

10. Close lower control compartment.