background image

IMPORTANT

Do not use abrasive cleaners

on glass. Never clean the glass

when it is hot.

• During start-up, it is normal for condensa-

tion to form on the inside of the glass (this

condensation and fog will usually disappear

in a few minutes). The moisture can cause

lint, dust and other airborne particles to cling

to the glass surface.

• Initial curing of the high temperature paint

and burning off of lubricants used in the

manufacturing process may result in a film

on the glass.

• A white coating may form on the glass as a

result of impurities and minerals in the fuel.

It is recommended that the glass be cleaned

two or three times during each heating season,

depending on the circumstances present. The

following cleaning solutions are approved for use

to clean glass:

• Non-ammonia based household cleaner

• 50%-50% mix of white vinegar & water

• Gas fireplace/stove glass cleaner

Inspect Glass Gasket - Visually inspect the

gasket on the backside of the glass enclosure

panel. The gasket surface must be clean, free

of irregularities and seated firmly.

Inspect Venting System

The appliance and venting system should be

thoroughly inspected before initial use and at

least annually by a qualified service technician

(inspection should include ensuring that exhaust

or intake passages are unobstructed and vent

components are properly assembled and not

damaged). If the venting system is disassembled

for any reason, a qualified service technician

should follow vent installation instructions for

proper reassembly and proper sealing of the

venting system components. However, more

frequent periodic inspections and cleanings

should be performed by the homeowner.

Clean Logs And Burner

Carefully remove the logs (use care when han-

dling the fiber logs, as they become quite fragile

after curing). Vacuum out any foreign matter

(lint, carbon, etc). on the burner. Ensure the

burner ports are “open.” Remove any carbon

deposits from the under side of the logs using

a vacuum cleaner, or a soft bristled brush (i.e.

paint brush). Note: Improper positioning of

logs can create carbon build-up and will alter

the performance of the appliance.

Replacing Logs -

If the logs become damaged by accident or

improper handling and need replacement, use

only the proper replacement logs from manufac-

turer (see Page 23 for ordering information).

WARNING

Label all wires prior to discon-

nection when servicing controls.

Wiring errors can cause improper

and dangerous operation. Verify

proper operation after servicing.

Re-Install Embers, Logs and Volcanic Stone

- Carefully follow placement instructions on

Pages 8 to 10 ). All logs should fit onto cor-

responding pins and/or log stoppers. This will

ensure a proper flame and safe combustion.
Inspect Wiring

Refer to wiring diagrams on Page 12.

6

Manually-Reset Spill Switch (limit disc)
ALLOW APPLIANCE TO COOL COMPLETELY

BEFORE ACCESSING AND RESETTING

This appliance is equipped with a manually-reset

blocked flue spill switch (limit disc). Refer to

Figure 6 for the location. If, during appliance

operation, the flame goes out (independently of

the burner on/off wall switch), it may be due to

the operation of this spill switch (limit disc).

First

allow the appliance to cool. Remove top louver

panel. Then reset the spill switch (limit disc) by

pushing the red reset button, located between the

wire terminals, on the back of the switch.

The appliance should then relight and remain

lit. Reinstall top louver panel. If the appliance

does not relight,

turn off the appliance and call

for a qualified service technician.
To replace the blocked flue spill switch (limit

disc) refer to Figures 6, 7 & 8:
NOTE -
This procedure should only be per-

formed by a qualified service technician.
Important - Turn electrical power off before

beginning this procedure.

1 - Remove the top louvered panel and the

bottom control compartment panel (see

Figure 1 on Page 4). Remove the glass

enclosure panel (see Removing Glass

Enclosure Panel on Page 7).

 - Remove the lintel securing screws (3) and

then remove the lintel. One of the lintel cabinet

top holes is shown in Figure 7).

 - Remove the scoop securing screws (3) and

then remove the scoop. See Figure 7.

4 - Remove the spill switch bracket securing

screws (2), and pull the switch/bracket

assembly, with low voltage wires attached,

through the side panel slot into the firebox.

See Figure 8.

5 - Replace the spill switch.

6 - Reinstall the switch/bracket assembly.

7 - Reinstall the scoop and lintel.

8 - Reinstall the glass enclosure panel.

9 - Re-Install the bottom control compartment

access door.

10 - The appliance should then relight and

remain lit. If this does not occur, check

unit for a blocked flue condition.

Spill Switch (Blocked Flue Safety Limit)

Location - See Figures 6, 7 & 8. Inside View

of Firebox - Top/Right Side Intersection

Figure 6

Wire

Terminals

Cabinet

Corner

Back of Spill

Switch (high

limit disc)

Door

Frame

Inspect and clean all wire connections. Ensure

that there is no melting or damage. Inspection

should include:

• Terminals at the Valve

• OFF/ON Switch

• (Optional Control Switch) OFF/ON Rocker

Switch, Remote Control or Remote Wall

Switch Kit

Inspect Burner Flame Appearance

Ensure that the burner flame appearance

resembles the flame shown in Figure 15 and

as described in Flame Appearance and Sooting

on Page 11. The Homeowner must contact

a qualified service technician at once if any

abnormal condition is observed.
Small Area Paint Touch-up

The finish of the appliance is a high qual-

ity powdercoat. Only use factory supplied

powdercoat paint kit for touch-ups. Paint is

available at your local authorized

Superior

Hearth Products dealer, cat. no. 90L74. Never

attempt to paint a hot fireplace.
Do not attempt to repaint the appliance until the

finish is completely cured (see Burn-In Period

on Page 4 ). If the surface later becomes stained

or marred, it may be lightly sanded and touched

up with spray paint.

VENT SPILLAGE TEST

After appliance installation, then periodicly

thereafter, perform this spillage test to verify

that proper venting conditions exist:

1 - Ensure glass enclosure panel is properly

installed.

2 - Close all doors and windows in the room.

Turn on all exhaust fans in the house.

3 - Light the appliance.

4 - Wait 15 minutes.

5 - To check for venting action, start by holding

a smoke producing device within an inch

of one edge (side edge, not top or bottom

edge) of one glass enclosure panel. The

smoke should be drawn toward the edge

of the glass enclosure panel. Continue the

test by moving the smoke producing device

along the entire length of both side-edges

of the glass door.

6 - If the smoke is not drawn towards the edges

of the glass door, turn off the appliance and

call a qualified service technican.