Sony XC-003 User Manual

Page 43

Advertising
background image

47

GEN LOCK

Lets you set the external sync mode.
NORMAL : Makes the HD/VD or VS signal the reference

signal according to the external input signal (automatic
switching).

R.R1 (restart/reset) : Inputs an external trigger signal

twice to control the start of shooting and the output
timing. The first signal initiates the charge; the second
signal completes the charge and outputs one field of the
image. You can also change the charging time for long
exposure.

R.R2 – R.R4 : Lets you set the charging time and the

image output relative to one trigger signal input as
given below.

D-SUB

Lets you select the output signal for the RGB/SYNC
connector.
VBS : Outputs a composite video signal.
Y/C : Outputs a Y/C signal.

R.R2

1 field

1 field

1

R.R3

1 field

2 fields

1

R.R4

2 fields

2 fields

1

Output

Charging
time

Mode

Trigger
pulse