NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

25

Figure 43 -

Millivolt Wiring Diagram

Field Wired

Factory

Wired

TH

TP

TH

TP

* Optional

Control Switch

Thermopile

Schematic
Representation
Only

• If any of the original wire as supplied must be

replaced, it must be replaced with Type AWM

105 C - 18 gage wire.

* Optional Kits Installed - ON/OFF wall switch, unit mounted burner ON/OFF switch, wall thermostat or

remote control.receiver.

HT

PT

HT

PT

*

* Twist wires together to operate unit

solely by manipulating the gas valve

control knob; or connect wires to

optional control switch (wall switch,

remote control or wall thermostat to

operate unit.

CAUTION: Label all wires prior to disconnec-

tion when servicing controls. Wiring errors can

cause improper and dangerous operation.

ATTENTION: Au moment de l'entretien des

commandes, étiquetez tous les fils avant de

les débrancher. Des erreurs de cáblage peu-

vent entraîner un fonctionnement inadéquat

et dangereux.

Verify proper operation after servicing.

S'assurer que l'appareil fonctionne adé-

quatement une fois l'entretien terminé.

CAUTION

Ground supply lead must be con-

nected to the wire attached to the

green ground screw located on the

outlet box. See Figure 46. Failure to

do so will result in a potential safety

hazard. The appliance must be

electrically grounded in accordance

with local codes or, in the absence of

local codes, the National Electrical

Code, ANSI/NFPA 70-latest edition.

(In Canada, the current CSA C22-1

Canadian Electrical Code).

Step 4. FIELD WIRING

Refer to Section A for millivolt appliances and

Section B for electronic appliances. The gas

valve is set in place and pre-wired at the factory

on both models.

A. Millivolt Wiring (See Figure 43):

1. Install and wire in the burner control switch.

Install either "a" or "b" below, NOT BOTH

(installing both may result in improper burner

operation).

a. Optional OFF/ON Switch - Install the OFF/

ON burner control switch (rocker switch)

as shown in Figures 43 and 44.

b. Optional Wall Switch, Wall Thermostat

Or Remote Control Receiver - Install snap

bushing (provided in Electrical Outlet

Kit - See Figure 44) into control switch

knock-out in side panel (see Figures 12

and 13 on Pages 10 and 11). Wire the

optional control switch within the millivolt

control circuit (as shown in Figure 43)

using the 15 feet of 2 conductor wire

supplied (route wires through the snap

bushing to the optional control switch).

Mount the optional control switch or wall

thermostat in a convenient location on a

wall near the fireplace.

CAUTION: Do not connect optional control

switch to 120V power supply.

2. Install the junction box and receptacle outlet

to the left of the valve in the front (for optional

blower kit). See junction box and receptacle

outlet as explained in steps 1-11 for (B)

Electronic Wiring (on this page).

Gas

Valve

Control Compartment

Access panel

OFF/ON

Switch

TP TH

TH

Install OFF/ON Switch

(millivolt models)

1. Connect the 2 wires (provided in Electrical

Outlet Kit) to the TP/TH and TH terminals

on valve.

2. Pass the 2 wires through the opening where

OFF/ON switch will be installed (left of piezo,

below valve).

3. Connect the two wires to the OFF/ON

Switch.

OFF/ON

Switch

Connect

wires to

terminals

4. Press the OFF/ON switch into bracket as

shown below (it will snap into place).

Figure 44

B. Electronic Wiring (See Figures 45 and

46)

Notes:

The electronic appliance must be connected

to the main 120 VAC power supply.

The junction box can be installed in any of the

4 outside corners of the control compartment

(it can be found factory installed in the right

front corner viewed from the valve access side

(where it should be reinstalled if an optional

blower kit is installed).

1. Route a 3-wire, 120 VAC, 60 Hz, 1 ph power

supply to the location on appliance where

junction box is to be installed.

2. Open the control compartment access panel

(see Control Compartment Access Instruc-

tions on Page 27).

3. Remove the junction box/outlet receptacle

assembly by removing the securing screw at

the front right corner of the unit. See Figure

45.

4. Remove the outlet receptacle from the

junction box by removing the two securing

screws.