Superior SSDVPF-CNE-B User Manual

Page 36

Advertising
background image

36

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

SIT Millivolt Gas Valve

Pilot for SIT Millivolt

Gas Valve

Figure 62

Step 6. See Figure 62 and remove the pilot
hood assembly to access the hexed pilot orifice.
Remove and replace the orifice with the one
provided with the kit.

Pressure

Regulator

Remove

These

Components

Figure 61

Pilot
Orifice

P

S

I

OF
F

I

ON

CONTROL

IG

N

IT

E

Gas Valve

Assembly

Manifold

Pressure

Test Port

Slotted

Cap

Spring

Adjusting

Screw

Figure 64

Figure 63

All Models

Step 9. (Refer to Figure 60 on Page 35 and

Figure 65 on Page 37)

VERIFY THE PROPER ORIFICE SIZES

BEFORE INSTALLING THEM.

A. Remove the two orifices from the manifold

and replace them with the ones provided in the

kit. Table 10 shows the orifice sizes for natural

and propane models. Figure 65 illustrates the

orifice. Use pipe joint compound or Teflon

tape on all pipe fittings before installing (en-

sure propane resistant compounds are used

in propane applications, do not use pipe joint

compounds on flare fittings).

B. Install rear burner first, followed by front

burner, as shown in Figure 66 on Page 37.

Ensure that the arm of the venturi of each burner

is hooked onto the air shutter adjustment lever

(refer to Figure 60 on Page 35). The primary air

opening can be adjusted by rotating the adjust-

ment lever from beneath the firebox floor. Refer

to Figure 57 on Page 31 for the recommended

minimum primary air opening setting.

NOTE: Each model has two burners and 2

Orifices.

Pilot

Orifice

Pilot

Assembly

Igniter

Assembly

Retaining

Clip

Flare Nut

Note: If the igniter is damaged, a replacement kit

is available, order Catalog No. 87L54.

Electronic Appliances

Step 7. Honeywell Electronic Valves - See

Figure 63 and the instructions provided with

the kit. Remove the slotted cap screw, o-ring,

pressure-regulating adjusting screw and spring.

Retain all parts for possible later use. Install

new components from the kit. Black cap and

red spring for propane gas appliances. Silver

cap and stainless steel spring for natural gas

appliances.

Step 8. See Figure 64 and replace the pilot

orifice as follows: Remove the igniter assembly

retainer clip, and carefully remove the igniter

assembly.

Remove the screw securing the pilot assembly

to its mounting bracket. Back off the flare nut

at the end of the pilot gas line to free the pilot

assembly from the gas line. Remove the pilot

orifice and replace it with the one provided with

the conversion kit. Reinstall the pilot assembly

by reversing the steps detailed here.

When reinstalling the igniter assembly, use

extreme care to prevent damage and break-

age. Do not apply any leverage to the igniter

assembly while restoring the retainer clip to

its original position.

Burner Orifice Sizes

Elevation 0-4500 feet ( 0-1372 meters)

Model

Series

Nat.Gas

drill size (inches)

Propane

drill size (inches)

SSDVST

SSDVPF

#44 (.086")

*

60J80 •

#55 (.052")

**

19L52 •

Table 10

* Standard size installed at factory

** Standard size in LP conversion kit

• Part /Cat. Number