Source Technologies 1352 MICR 40 User Manual

Page 40

Advertising
background image

Secure MICR Printer User’s Guide

©

Source Technologies

July 2003

Page 36

All rights reserved

Audit Trail Report Command Set

&%SAR$

Start Audit Record

&%SAR

Lead in sequence

$

Command terminator

Marks the start of an audit record and begins a PJL job.. This command must be inserted in
the datastream after MICR Mode is entered and before the first flagged field appears. It
should be sent at the beginning of each check record.

End Audit Record

&%STORE$

&%STORE

Lead in sequence

$

Command terminator

Ends the Audit Record and the PJL job (ignored if there was no Start Audit Record
Command).

Audit Report Field One

&%SQ1d..d$

&%SQ1

Lead in sequence

d..d

Data to be stored

$

Command terminator

This command identifies the data to be printed in the first column of the report. It is a
maximum of 14 characters in length. If less than 14 characters are sent, the printer fills the
field with spaces when the audit report is printed. This field is recorded in the audit report
only, it is not printed on the check.

Audit Report Field Two-MICR Line

&%SMDd..d$ or &%SM7d..d$

&%SMD or &%SM7

Lead in sequence

d..d

Data to be printed

$

Command terminator

This command identifies the data to be printed in the second column of the report. It is a
maximum of 40 characters in length.

Audit Report Field Three

&%SQ3d..d$

&%SQ3

Lead in sequence

d..d

Data to be printed

$

Command terminator

This command identifies the data to be printed in the third column of the report. It is a
maximum of 40 characters.

Section 8: Audit Trail Reports