Step 9: pneumatic control installation – Stellar Industries SI-60 User Manual

Page 38

Advertising
background image

32

Stellar Cable Hoist Owner’s Manual

Step 9: Pneumatic Control Installation

The pneumatic controller provided with the Stellar Cable Hoist are dual three-way regulat-

ing valves. Output of the controllers is proportional to the control lever position and is bal-

anced against the force of an internal spring.

Pneumatic Actuator Installation:

The pneumatic actuator has been partially assembled and pre-lubricated for ease of

installation. The actuator does not have to be disassembled for installation.

1. Remove the valve from the hydraulic tank if previously installed.

2. Find a suitable area free of dust and dirt to attach the pneumatic actuators.

3. Set the hydraulic valve on its mounting base.

4. Determine which spools are to be pneumatically controlled.

5. From the valve assembly:

a. Remove and discard the 1/4” retainer screws

and the valve spring cover.

b. Retain the handle end of the spool. Using a

5/16” hex Allen wrench, remove and discard

the 3/8” shoulder bolt and washer from the

end of the valve spool exposed by the

removal of the valve spring cover. Note: It

may be necessary to give the hex Allen

wrench a sharp rap to break the socket head

screw loose.

c. Remove and discard the original centering spring. Keep the two original centering

cups and the sleeve for reuse.

d. Ensure the original seal retainer on the valve spool is properly seated.

6. Assemble the new centering spring (item 2)

supplied with the pneumatic actuator using

the original centering cups and sleeve as

shown.

7. Apply a small bead of removable thread lock

to the threads of the spool adapter (item 2).

Holding the spool on the opposing end, hand

tighten (torque 45-50 in-lbs) in the centering

spring assembly by inserting 1/4” hex wrench

through the rear fitting port into the end of the

piston (Item 13). Do not use an air gun. Make

certain that the spring assembly does not bind

on the centering cups.

8. Make certain the o-ring (item 15) is in place.

Secure the pneumatic actuator assembly to

the valve body using the four socket head

screws and lock washers (Items 4 & 5). Test for

proper alignment by turning the valve spool.

The spool should rotate freely.

9. Assemble the valve to the mounting plate on

the hydraulic tank. Test spool for free move-

ment.

Hex. Slot

Spool

Centering Cups

Apply Removable

Threadlock Here.

Seal Retainer

Tighten the assembly by hand using

a 1/4” Hex. Wrench Max. Torque 45-50 in-lbs

Do not use an air gun.

Advertising