STATUS INDICATORS

When the following indicators light up or blink on the operation panel or the following alphanumeric codes
appear in the display, solve the problem immediately referring to both the table below and the relevant page.

Be sure to use only genuine SHARP parts and supplies.

Indication

Cause and remedy

Page

Developer

replacement required

indicator

Steadily

lit

Developer is required. contact your authorised

service representative.

56

Toner cartridge

replacement required

indicator

Steadily

lit

Replacement of Toner cartridge will be needed soon.

Prepare a new cartridge. (AR-208T)

45

Blinking Toner cartridge must be replaced. Replace it with a

new one. (AR-208T)

45

Misfeed indicator

Blinking

A misfeed has occurred. Remove the misfed paper

referring to the description of "MISFEED REMOVAL".

52

The lower side cover may be open. If so, close it.

55

Maintenance

indicator

Steadily

lit

Service by an authorised SHARP service technician

is required.

56

SPF misfeed

indicator

Blinking

An original misfeed has occurred in the SPF. Remove

the misfed originals referring to the description of "E:

Misfeed in the SPF".

55

Power save indicator is steadily

lit.

The unit is in the preheat mode. Press any key to

cancel the preheat mode.

42

The unit is in the auto power shut-off mode. Press the

start (

) key to cancel the auto power shut-off

mode.

42

The paper tray indicator is

blinking.

The paper tray is not installed properly. Push the tray

into the unit securely.

"CH" is blinking in the display.

The toner cartridge is not installed. Check if the

cartridge is installed. If "CH" is blinking even if a

cartridge is installed properly, contact your SHARP

service centre immediately.

"CH" is steadily lit in the display.

Side cover is open. Close the side cover securely by

pressing the round projections near the side cover

open button.

"P" is blinking in the display.

The paper tray or multi-bypass tray is empty.

Load paper.

8, 10

A misfeed has occurred in the paper tray, single

bypass or multi-bypass tray. Remove the misfed

paper.

52

Paper tray is not securely installed. Push the tray in

securely.

A letter and a number appear

alternately.

The scan head locking switch is locked. Unlock the

scan head locking switch and turn the power switch

off/on.

57

A letter and a number appear

alternately.

The unit will not function. Turn the power switch off

and then switch it on, and if there is again an error,

remove the power cord from the outlet, and contact

your authorized service representative.

A letter and a number appear

alternately.

The unit will not function. Turn the power switch off

and then switch it on, or when the side cover is

opened and then closed ; and if there is again an

error, check whether or not you forgot to remove the

bundling tape on the cartridge.