Safety related adjustment – Sony AEP MODEL CPD-E200E User Manual

Page 16

Advertising
background image

CPD-E200E

SECTION 3

SAFETY RELATED ADJUSTMENT

Part Replaced (

[

)

RV501

HV ADJ

When replacing or repairing the shown below table, the

following operational checks must be performed as a

safety precaution against X-rays emissions from the unit.

HV Protector Circuit Check

Using an external DC Power Supply, apply the voltage

shown below between cathode of D517 on D board and

GND, and confirm that the HV HOLD DOWN circuite

works. (TV Raster disappears)

Standard voltage : 35.80

±

0.01 V DC

Check Condition

• Input voltage : 120

±

2 V AC

• Input signal

: White cross hatch at 69.0kHz

• Beam control : CONT : min, BRT : min

Beam Current Protector Check

An ammeter in series between FBT pin !] on D board

and GND, then, decrease gradually the resistance of the

variable resistor from maximum to minimum, and con-

firm that the Beam Current Protector Circuite works

(TV Raster disappears). The current must be within the

range shown below.

• Standard current : 1.55

+0.00

mA

Check Condition

• Input voltage : 120

±

2 V AC

• Input signal

: White cross hatch at 31.0kHz

• Beam control : CONT : min, BRT : min

B+ Voltage Check

Standard voltage : 179.0

±

3.0 V DC

Check Condition

• Input voltage : 120

±

2V AC

Note : Use NF power supply or make sure that

distortion factor is 3% or less.

• Input signal

: White cross hatch at 69.0 kHz

• Beam control : CONT : max, BRT : center

HV Regulator
Circuit Check

HV Protector
Circuit Check

Beam Current
Protector Circuit
Check

Part Replaced (

]

)

D board IC501, C532, C534,

C539, C553, C554,
C555, C556, C558,
C561, R541, R542,
R544, R564, R567,
R568, RV501,
T501 (FBT)

D board IC607, IC901, D515,

D517, C540, C542,
C544, R510, R543
R547, R549, R552,
R595,
T501 (FBT)

D board IC605, IC607, IC901,

C535, C541, R545,
R546, R548, R550,
R596, R934,
T501 (FBT)

*

Confirm one minute later turning on the power.

3-1

-0.10

HV Regulator Check

1) Input cross hatch signal (white lines on black).

: fH = 69.0kHz

2) CONT maximum and BRT center.

3) Cut off Screen VR (G2).

4) Input voltage : 120

±

2 VAC

5) Confirm that the voltage is within the voltage range

shown below.

Standard voltage : 27.0kV

±

0.2kV DC

6) When replacing components identified by

]

, make

sure to recheck the High Voltage.

7) Verify the High Voltage as shown above (27.0 kV

±

0.2kV) is within specification. If not, set H. SIZE

data at minimum (-127) and then adjust RV501 on

"D" Board.

8) After adjusting the High Voltage within specifica-

tion, put the RV cover on RV501 as shown below

and apply sufficient amount of RTV around RV501.

RV501

104

Advertising