6.3.96

In order to test the interface and your settings, enter AT. The GSM module should then
respond with OK. If it does not do so, configure a different interface in the communi-
cation program and try again. Also check the cable. When this test has been success-
fully completed, check the functionality of the GSM module by entering AT&T1. This
command activates a test loop. From now on, all the characters entered from your
GSM module should be echoed on the computer. Terminate the test by entering the
escape sequence +++. If the test is acknowledged by the NO CARRIER code, the
GSM module’s data functionality is operating correctly.

The transfer rate (baud rate) via the radio interface can be set, for example, using a ter-
minal program. The ATBn command allows you to set the transfer rate in the GSM net-
work.

Enter the ATI8 command to display the current list.

Example:

Enter:

ATB13

M1

Permanently switches mode to 9600 bit/s.

Enter:

ATB7

M1

Permanently switches mode to 2400 bit/s.

Setting the GSM radio transfer rate

ATBn

[n=7,11,13,25,27,29,70,99]

Option

Effect

Bit/s

Synchronism

Distant station

ATB99

9600

Asynchronous

Mode set to automode

ATB7

2400

Asynchronous

V.22bis

ATB11

4800

Asynchronous

V.32

ATB13

9600

Asynchronous

V.32

ATB25

2400

Asynchronous

V.110 ISDN

ATB27

4800

Asynchronous

V.110 ISDN

ATB29

9600

Asynchronous

V.110 ISDN

ATB70

9600

Fax

Fax Group 3