26.2.96

This command selects the bearer service with data rate and the connection element
to be used when data calls are originated.

AT+CBST - Select bearer service type

AT+CBST

Command

Result

AT+CBST=[<speed>
[,<name>[,<ce>]]]

Selects new speed, name and ce

AT+CBST?

Displays speed, name and ce

AT+CBST=?

Displays list of supported speed, list of supported
name and list of supported ce (Connection Ele-
ments)

<speed n>

n=[0,4,6,7,68,70,71]

0

autobauding

4

2400 bps (V.22bis)

6

4800 bps (V.32)

7

9600 bps (V.32)

68

2400 bps (V.110)

70

4800 bps (V.110)

71

9600 bps (V.110)

<name n>

n=[0]

0

asynchronous modem

<ce n>

n=[0]

0

transparent