Siemens M1 User Manual

Page 8

Advertising
background image

7

GSM M1 Module, English: A24859-N4000-A100-1-7677

gsm-m1-e.fm

6.3.96

Installation / startup

Two standard options are available for mounting the GSM Module M1 :

• Retaining clip

• Velcro

Before applying the velcro, make sure that the surface of the M1 (recess provided in
center of base) and the corresponding surface are free of dust and oil.

The mounting location must comply with the following environmental conditions:

• Temperature range -20 °C – +55 °C for full operability

• Temperature from insolation < 110 °C

• Light condensation permissible

Power is supplied via the cable included in the scope of supply. The relevant wires are
marked as follows:

Red

POWER +8 V – +24 V DC

Violet

IGNITION(ON/OFF)

Brown

GND

Ground

The GSM Module M1 switches on when a positive voltage of 5 - 24 V is applied to IG-
NITION if a voltage of 8 - 24 V is simultaneously applied to POWER.

The module switches off when a voltage of less than +1 V is applied to IGNITION. An
existing call is correctly disconnected. This voltage must be applied for a minimum of
550 ms.

Important:

Be sure to switch off the module using IGNITION; simply disconnecting the power sup-
ply at POWER can damage the SIM if it is being written to at the time.

Nominal voltage:

13,2 V DC

Extreme voltage:

8 - 32 V DC

Mounting the module

Power supply / power consumption

Cable assignment

Switching the GSM module on/off

Voltage range

Advertising