Clock generation

Internally generated sample rate

(c) Spectrum GmbH

57

External clock with divider

The extra clock divider can be used to divide an external fed in clock by a fixed value. The external clock must be > 1 MS/s. This divided
clock is used as a sample clock for the board.

Available divider values

Register

Value

Direction

Description

SPC_CLOCKDIV

20040

r/w

Extra clock divider for external samplerate. Allowed values are listed below

1

2

4

8

10

16

20

40

50

80

100

200

400

500

800

1000

2000