70

Sensor In: Outputs an alarm signal when the specified external sensor input terminal receives an input.

Motion On: Outputs an alarm signal when the specified video input terminal receives a motion detection

signal.

Video Loss On: Outputs an alarm signal when a video loss occurs in the specified video input terminal.

Alarm Duration: Sets the duration of the alarm output signal

Error Alarm: Sets whether to output or not an alarm signal when the error condition occurs.

(Options are OFF, ALL, HDD ERROR and VIDEO LOSS.)

Remote Controller: Sets an ID number on the supplied remote control for its identification.

Setting the PTZ Control: Sets the communication environment for remotely operating PTZ dome cameras

connected to RS485 terminals.

Camera Channel Designation

Camera Speed: Sets the communication speed. The set value applies to all channels.

Protocol: Sets the protocol type for the specified channel. When connecting multiple cameras, set the

same protocol for all.

Camera ID: Sets the camera ID.