Editing, Band dynamic eq – SIGMA EQ Station User Manual

Page 26

Advertising
background image

EDITING

24

3-Band Dynamic EQ

EQ Type
Two different types of Dynamic EQ can be selected:
3-Band Full-range or 2 band ParaDyn.

The Dynamic EQ enables you to shape your sound
depending on energy in the signal, or to notch out specific
level dependent problems.

Three band Dynamic EQ

Two cross-over points and three sets of parameters,
enables individual setting of Lo, Mid and Hi performance
for the dynamic EQ.

This type of Dynamic EQ is typically used as a creative tool
that shapes the entire signal but can of course also be
used for system protection. In terms of creativity this type
of EQ-ing can be compared to what Mastering engineers
often do when shaping a master-mix.
The two set Crossover points defines the three bands each
holding its own individual set of the parameters described
below.

Threshold

Range: 0 to -45dBFS

When the Input signal exceeds the Threshold value the

Dynamic EQ starts to reduce the dynamic content of the

signal according to the set Ratio in the selected band.

- Regarding headroom

The Threshold always has a headroom of 45dB, but the

range is scalable with the ADA card settings on the; Setup

page-I/O Configuration-ADA I/O Settings-ADA gain.

Example:

With the ADA gain set at +21dB with Off set at 0dB, the

Threshold setting is 21dB and down to -24dB.

Ratio

Range: Off to Infinity

Specifies the Ratio of the performed compression on the

selected band.

Example:

With a Ratio setting of 2:1 the Compressor will reduce

every 2dB above the Threshold point to only 1dB.

Attack

Range: 0.3 to 100ms

The Attack time is the time the Dynamic EQ uses to reach

the gain reduction specified by the Ratio parameter in the

selected band.

Example:

If the Input signal increases by 4dB above the set

Threshold with a Ratio set to 2:1 and the Attack time set to

20ms, the Compressor will use 20ms to reach a Gain

reduction of 2dB.

Release

Range: 20ms to 7 sec.

The fallback time. The time it takes for the Dynamic EQ to

release the attenuation of the signal in the selected band.

MakeUp

Range: 0 to12dB

Manual Make-up gain for each compression band.

Cross Over 1

Range: Off to 3.15kHz

Defines the Crossover point between the lower and middle

compression bands.

Bandwidth knob functions.
Via the menu point “GraphEQ width” in the Utility menu you
can assign which of the following three functions should be
assigned to the BANDWIDTH knob:

Frequency:

The function of the FREQUENCY knob is
duplicated to the BANDWIDTH knob.

Sweep:

Set gain and sweep this gain setting
through the frequencies using the
BANDWIDTH knob.

Width:

In Width mode the BANDWIDTH knob can
be used to increase the frequency area with
center in the selected frequency.

Mirror:

Select mirror-mode and use the
BANDWIDTH and the GAIN encoder to
mirror frequencies in O dB

Curve:

Select curve-mode and use the
BANDWIDTH encoder to select more than
one frequency. Cut and boost frequencies in
curves. +/-3dB peer 1/3 oct.

Advertising