Bbr-79-1 venting installation – Southern Pride SPK-700-SL User Manual

Page 13

Advertising
background image

48

13/32"

18

1/32"

20"

BBR-79-1

VENTING INSTALLATION

9/15/04

ANY VENTILATION SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES.

CONSULT WITH LOCAL OFFICIALS AND A COMMERCIAL KITCHEN VENTILATION

CONTRACTOR PRIOR TO INSTALLATION.

The oven’s minimum clearances from combustible materials are 18" on left side, 24" on right, 18" on top,
48" from front, and 2" on back. Minimum clearances 18" to chimney connector and to smoke extractor chimney
connector. Floor may be constructed of a combustible material. (Note: minimum clearance dimensions are from
the oven cabinet, not from component cover.) (If provision is made for access to service, minimum clearance can
be reduced to 2" on left side.) May be installed through wall with zero clearance with BBR kit No. 2099.

*

**

*

*

HOOD SYSTEM TO INCLUDE:

1. Ventilation Hood
2. Two speed fan (1380/2000)
3. Curb with vented extension and hinge kit
(Specify roof pitch)
4. Grease capture trough
5. Combustion chamber flue vent

SUPPLIED BY CUSTOMER:

6. Duct from hood to fan

VSP HOODS are U/L Listed to the applicable
Southern Pride oven models and are NSF Certified.

BBR-79-1-FL with recommended
optional VSP Vent Hood System.

VSP HOOD SYSTEM:

Purchased through Southern Pride

ALL MODELS MAY ALSO BE INSTALLED UNDER A CANOPY HOOD RATED

FOR COMMERCIAL COOKING APPLIANCES.

1

2

4

5

6

NOTE: If you have a duct longer than 10 feet or an
elbow in your duct your installation, it may require a
larger capacity exhaust fan. Please specify your duct
requirements when ordering the VSP Hood System.

Southern Pride Distributing, L.L.C.

Phone: 618-997-9348

2102 East Main Street - Marion, Illinois 62959

Fax: 618-993-5960

www.southern-pride.com [email protected] [email protected] [email protected]

Sales: 800-851-8180 Service: 800-437-2679 Service Fax: 618-993-0378

Advertising