5 hot plug support – SUPER MICRO Computer AOC-USAS-L4i User Manual

Page 27

Advertising
background image

3-11

Safety Information and Technical Specifications

4. When rebuild is complete, the CU displays the message:

Rebuilding of Drive X Completed Successfully. Press Esc. (X = the ID of the
rebuilt drive.)

5. Press Esc to display the Management Menu.

The state of the rebuilt disk drive changes from FAIL to ONLIN.

If you press Esc while the rebuild is running, the following options display:

• Stop: (Available only if AutoResume is enabled on the adapter: Management

Menu -> Objects -> Adapter -> AutoResume.) The rebuild is stopped, and the
CU stores the percentage of the rebuild already completed. If AutoResume is
enabled, the rebuild resumes where it left off when you restart it, instead of start-
ing over from 0 percent.

• Continue: The rebuild continues normally.

• Abort: The rebuild is completely aborted and the disk drive remains in the FAIL

state. If you restart the rebuild, it begins at 0 percent.

3-5 Hot Plug Support

The MegaRAID BIOS CU supports hot plugging of disk drives. The following hot
plug message will appear when you insert or remove a disk drive: A Drive Has
Been Inserted/Removed. Configuration Updated. Press ESC... After you press Esc
the inserted or removed drive will be reflected in the list of drives that appears in
the configuration utility.

You should not insert or remove a drive while you are defining a new logical drive
or while an initialization or other process is running. The following bullets describe
how the CU handles hot plugging when various actions occur:

• If the Physical Drive window or one of the Configuration windows is open when

you insert or remove a drive, the window will close when the hot plug message
appears.

Advertising
This manual is related to the following products: