Step 4: Water Connection

!

WARNING

Do not connect steamer to a hot water line. A hot water connection will damage the steamer.

NOTICE

To meet warranty requirements, the supply water must meet the following specifications:

Pressure

30 to 60 PSI

Total Dissolved Solids (TDS)

60 PPM

Hardness

2 grains or 35 PPM

pH

7.0 to 7.5

Connect a cold water line to the water inlet strainer on the back of the steamer, as shown in Figure 4 on
page 9. The connector on the unit is 1/4" NPT male.

NOTE: To facilitate cleaning, and allow access to rear of unit, flexible connections are recommended. A shut
off valve at (or near) the rear of the unit is highly recommended. See Figure 5 below.

Figure 5

Check

Valve

Filter

Steamer

Cold

Water

Supply

Shut Off

Valve