7. connection, 7-1. attaching the clamp filters (hdw series only) – Sony HDW-2000 User Manual

Page 14

Advertising
background image

1-8

HDW-2000/M2000/M2000P/S2000/S2000P/M2100/M2100P, DVW-2000/2000P/M2000/M2000P

MSW-2000/A2000/A2000P/M2000/M2000P/M2000E/M2000EP/M2100/M2100P/M2100E/M2100EP

21. Slide the unit in and out from the rack about three

times and check that the slide rails move smoothly.
If they are not smoothly, demount the unit and go back
to “Attaching the outer rails” (step 12).
c
When demounting the unit, carry it by the two persons
or more.
n
This unit does not have the feet at this operating.
Put down the unit on the floor or other, being careful
not to damage the unit.

22. Push the unit in the depths of the rack. The unit is

fixed to the rack by the lock mechanism.
Attempt to pull the rack angles and confirm that the
unit cannot be pulled out of the rack.
w
When installing the unit in an Outside Broadcasting
van, be sure to fix the unit to the rack using the screws
and ornamental washers supplied with the rack mount
kit.
Tightening torque: 120

x 10

_2

N

. m {12.2 kgf . cm}

n
When the unit is not fixed to the rack or the clearances
between the rack angle and rack are existed, it is
necessary to perform the adjustment for the lock
mechanism.
Refer to the RMM-131 installation guide for more
detailed information.

1-6. Rack Mounting
1-7. Connection

Ornamental
washer

Release button

Release button

RK5

x 14

Ornamental washer

RK5

x 14

1-7. Connection

1-7-1. Attaching the Clamp Filters (HDW

Series Only)

In the case of HDW series, to make the unit compliant with
the EMC regulation, be sure to attach the clamp filter on
each XLR cable connected to the following connectors.
n
In the case of DVW series and MSW series, it is not
required.

Supplied Accessories
Clamp filter (1-543-798-21) 6 pieces (Recorder)

or 4 pieces (Player)

Connectors of the XLR Cables
Required Attachment of the Clamp Filters
. MONITOR OUT L
. MONITOR OUT R
. TIME CODE IN (Recorder only)
. TIME CODE OUT
. CUE IN (Recorder only)
. CUE OUT

Attaching Position
Snap on the clamp filter at the place 50 to 150 mm away
from the connector plug of the XLR cable.

XLR connector plug

Clamp filter

50 to 150 mm

Advertising