1-15. Settings and Adjustment when External Equipment is Connected

1-15-1. Settings for Time Code (Recorder Only)

To set the TIME CODE, open the P1 page (TCG/TCR SETTING) on the function screen.

When Editing with an Editor (BVE-2000, etc.) Capable of the 1st Edit
When this unit is used by connecting to an editor, set as follows.

Button

Model

Item (Display)

Setting

F1

HDW

TCG SOURCE (TCG)

INT

DVW/MSW

TCG INT/EXT (TCG)

F2

HDW

TCG PRESET/REGEN (PR/RGN)

PRESET

DVW/MSW

TCG PRESET/REGEN (TCG)

F3

HDW

TCG RUN (RUN)

FREE

DVW/MSW

TCG RUN (RUN)

When Editing with Direct Machine-to-Machine (VTR to VTR)
n
The setup menu ITEM-610: REGEN CONTROL MODE setting data must be set to “AS&IN”.

Button

Model

Item (Display)

Setting

F1

HDW

TCG SOURCE (TCG)

INT

DVW/MSW

TCG INT/EXT (TCG)

F2

HDW

TCG PRESET/REGEN (PR/RGN)

PRESET

DVW/MSW

TCG PRESET/REGEN (TCG)

F3

HDW

TCG RUN (RUN)

FREE

DVW/MSW

TCG RUN (RUN)

REC

1-15. Settings and Adjustment when External Equipment is Connected