SECTION 5

TROUBLESHOOTING

SYMPTOM

POSSIBLE SOLUTION

Controller does not power up.

Check: tuner is connected to power supply.

controller is connected to tuner.

power supply is plugged into 110 VAC outlet.

Controller remains in one of the
following conditions:

POWER TRIP

ANT COM ERROR?

TUNER COM ERROR?

Unplug tuner for 10 seconds, then plug back in.

Check coax cables and connections between tuner and dome unit.

Verify voltage on coax at dome unit is 24 volts.

Controller displays AZ FAULT.
Dish cannot rotate.

Make sure shipping bolt is removed (see Page 7).

Disconnect power supply for 15 seconds, then reconnect.

Perform Mechanical Calibration (page 26).

Perform OPTION 21 RE-INITIALIZE and 0-RECALIBRATE (pages 24-25).

Reseat ribbon cables (inside dome unit).

Display reads EL FAULT.

Make sure shipping bolt is removed (see page 7).

Disconnect power supply for 15 seconds, then reconnect.

Perform Mechanical Calibration (page 26).

Restart system. If problem persists, perform OPTION 21 RE-INITIALIZE
and 0-RECALIBRATE
(pages 24-25).

Reseat ribbon cables inside dome unit.