SPECIAL MESSAGES FROM THE TURNTABLE

The following messages are shown on the screen to protect your reception system and the on-board
power supply:

SYSTEM PROTECTION MESSAGES

The power supply to the turntable is inadequate (battery voltage below the minimum value). The turntable
can still be moved, but communication errors can occur between the UFS 740sw and the turntable
(e.g. when scanning for satellites).

If the voltage falls still further, both the following error messages are displayed:

Check the power supply to the turntable and
whether it is obstructed (e.g. by a branch). If both
causes of faults are displayed, the turntable motor
temperature is in the critical range. Allow the
turntable to stand for a few minutes in its current
position, until the turntable motor temperature has
reduced. You can also however move the turntable
to the park position and let it cool down there.

Press the



button and the turntable will move

to the park position.

Press the



button to acknowledge the displayed

message. The turntable cannot be moved any
more. Check the power supply to the turntable.

Note:

The antenna should not be moved whilst the battery is being recharged, to prevent peak
loads when turning on.