Scanner control dialog box, Multi-feed detection options – Kodak i55 User Manual

Page 69

Advertising
background image

A-61527 May 2006

65

Scanner Control
dialog box

Selecting the Scanner Control button on the More Scanner Settings
dialog box displays the Scanner Control dialog box.

This dialog box allows you to set multi-feed detection and transport
control. The settings in this dialog box do not affect the quality of the
image.

OK

 saves the values set on the dialog box.

Cancel

 closes the dialog box without saving any changes.

Multi-Feed Detection
options

Length Detection

 this option can be enabled or disabled. The

default is disabled. If Length Detection is enabled, enter the maximum
length. This is the minimum length of the document that can be
scanned with a multi-feed being detected. Length detection is used
when scanning same-sized documents to check for overlap. For
example, if you are scanning 8.5 x 11-inch (A4) documents in portrait
mode, you may want to enter a value of 11.25 inches (28.57 cm) in the
Maximum Length field.

Units — defines the primary measurement system. Pixels, Inches,
and Centimeters are available.

Auto Set

 when enabled, will automatically set the maximum length

value to .50-inch (1.27 cm) greater than the length of the currently
selected page size.

Stop scanner on Multi-Feed — when enabled, the scanner will stop
when a multi-feed is encountered.

Sound Alarm on Multi-Feed — when enabled, the scanner will alert
you with the sound you selected when a multi-feed is encountered.

Sound — select this option to choose the sound you would like your
PC to make to alert you of a multi-fed document.

To choose a sound:

1. Click on the Sound button to display the Open dialog box.

2. Choose the desired .wav file.

3. Click Open on the dialog box and the sound will be saved.

Advertising
This manual is related to the following products:

I65