B. OPERATING SEQUENCE

Refer to the chart at right for the proper operating
sequence.

1.

Turn on the whirlpool jets. Adjust each jet for
optimum air/water mixture.

2.

A built-in timer automatically stops the motor after
approximately 20 minutes of operation.

3.

A built-in heater automatically maintains the water
temperature while whirlpool bathing.

Reduce
Air and
Water

Add Air
and
Water

TO

METHOD

OBSERVE

Turn on
whirlpool
massage and
the heater.

Decrease flow by
pressing

key;

increase flow by
pressing

key.

To add air and
water to whirlpool
action, rotate
the trim ring
counterclockwise.
To reduce air and
water, rotate it
clockwise.

Shut off whirlpool.

Restart whirlpool
after 20 minute
cycle is
complete.

Up/
More

Down/
Less

14. TROUBLESHOOTING PROCEDURES

A. FLEXJET INSTALLATION

NOTE: The Flexjet O-ring must be correctly positioned,
must be lubricated, and must be in good condition to
permit easy rotation and proper operation.

1.

Install the O-ring onto the first shoulder of the
Flexjet. Lubricate the O-ring with silicone lubricant
to prevent noisy operation of the Flexjet.

2.

Insert the Flexjet into the housing, and lightly push
and rotate the Flexjet until it snaps into position. Do
not force the Flexjet.

NOTE: When installed correctly, the Flexjet should turn
smoothly both clockwise and counterclockwise.

Flexjet Housing

O-Ring (Must
Be Lubricated)

Flexjet

Slide O-Ring