Kohler Freewill Barier Free Bath Whirlpools K-12106-H User Manual

Page 16

Advertising
background image

16

115982-2-

BA

(-)

Kohler Co., Kohler, WI

B. TROUBLESHOOT WHIRLPOOL SYSTEM

This troubleshooting guide is for general aid only. A Kohler Authorized Service Representative or a qualified electrician
should correct all electrical problems. For warranty service, contact your dealer or wholesale distributor.

SYMPTOMS

PROBABLE CAUSES

RECOMMENDED ACTION

1. Whirlpool does not

start/stop.

A. No power to pump/control.

A. Set/Reset GFCI; check wiring to

pump/receptacle.

B. Jets are blocked.

B. Remove blockage.

C. Switch disconnected from

pump/control box.

C. Reconnect switch to pump/control

box.

D. Switch faulty.

D. Replace switch.

E. Faulty circuit board.

E. Replace circuit board inside

pump/control box.

F. Faulty motor/pump assembly.

F. Replace motor and pump.

2. Motor starts, all jets

are not functioning

A. Jet is closed.

A. Rotate jets counterclockwise to open.

are not functioning.

B. Trim kit installed incorrectly.

B. Reinstall trim kit, checking for damage

to O-ring.

3. Whirlpool stops

automatically

A. GFCI trips.

A. Identify source of fault and correct.

automatically
before 18 minutes.

B. Suction blocked.

B. Remove obstruction.

before 18 minutes.

C. Jets are blocked.

C. Remove blockage.

D. Motor overheated and protection

device activated.

D. Check for blockage at motor vents.

Remove blockage and allow motor to
cool.

Check for suction blockage. Remove
blockage and allow motor to cool.

Check for jet blockage. Remove
blockage and allow motor to cool.

E. Faulty circuit board.

E. Replace circuit board inside

pump/control box.

4. Whirlpool does not

automatically stop
after 22 minutes.

A. Faulty circuit board.

A. Replace circuit board inside

pump/control box.

5. Pump does not

prime.

A. Pump shimmed too high.

A. Lower pump/control to subfloor level

that bath is resting upon.

6. Noisy operation.

A. Pump straps have not been cut.

A. Cut straps with tin snips.

B. Jet squeals due to dislodged jet

O-ring.

B. Remove jet, replace and lubricate

O-ring on valve body, and reinstall jet.

Advertising
This manual is related to the following products: