1. ROUGHING-IN: K-12105-H*, K-12106-H*

A. ORDERING INFORMATION

Applicable product:

Left outlet

K-12105

shown

Right outlet

K-12106

not shown

Accessories/hardware:
Drain

K-7161-AF

recommended

Jet trim kit

K-9696

required

MasterShower
Handshower

K-9500

recommended*

Paladar valve only trim

K-T14542-4 recommended

Paladar Rite-Temp valve

K-304-K

recommended

Bath spout

K-6855

recommended

Dome light

K-1570

optional

Glassworks bypass door
or
Forum bypass door

K-9864

K-703012

optional

* Dimensions illustrated

B. REQUIRED ELECTRICAL SERVICE

Dedicated branch circuit required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):

Pump/control

120 V, 20 A, 60 Hz

C. PRODUCT INFORMATION

ADA compliant
Fixture*:

basin area

top area

weight

Bathing well

44” x 23”

51” x 26”

265 lbs.

water depth

capacity

To overflow

13”

55 gals.

Configuration

1-piece

Drain Outlet

2-1/4” D.

* Approximate measurements for comparison only.

Pump

high HP low HP

V

Hz

A

2-speed

1

1/8

120 60

16.5

D. INSTALLATION NOTES

Read the entire installation instruction before beginning the
installation.

Unit is not drilled for supply fittings.

Shimming may be required to level fixture.

For optimum accessibility, specify faucets and fittings to
install and operate within the control area shown.

Pump is supplied with a grounding-type plug-in cord. Locate
the outlet behind the whirlpool, and within 24” of the pump.

ROUGHING-IN NOTES

Fixture conforms to ANSI Standard Z124.2. All dimen-
sions are nominal.

* Recess opening must be 65” x 84-1/4”.

No change in measurements if connected with drain il-
lustrated.

Minimum access panel:

Pump/control

20” W x 15” H

required

Stud opening tolerance (+ 1/4” – 0”). When fire rated
wall is specified, dimensions are to the inside of the wall
board. Some shimming between stud frame and fixture
may be required.
Provide clear floor space per ANSI A117.1, and as
shown.

ЛЛЛЛЛЛ

Represents control area for faucets.

ЙЙЙЙЙЙ

Represents 24” wall mount slide bar.

36”

60”

Represents clear floor space for 36”
x 60” side entrance.

48”

60”

Represents clear floor space for 48”
x 60” side entrance.