Ndeleting the selected file ([delete] button) – Konica Minolta Polygon Editing Tool User Manual

Page 72

Advertising
background image

70

Chapter

2

File
Menu

910

File – Import – Digitizer – PC Card (When VIVID 910 is Selected)

Parameters for [File-Import-Digitizer-PC Card-Load] Dialog Box

Element name

Enter the desired element name.

Reduction Rate

Selects the reduction rate to be applied when importing the data. You can select any of the following:
“1/1”, “1/4”, “1/9”, “1/16”, or “No polygon”.

Fill Holes

Selects whether the programs fill in holes when importing the data. If the setting is On, the pro-
gram will automatically generate points to fill in holes left by missing data.

Remove

Selects which the data the program excludes when carrying out the import. Select from an of the fol-
lowing: “None”, “Boundary (B.)”, “5deg. & B.”, “10deg. & B.”, “15deg. & B.”, or “20deg. & B.”

None:

Removal is not carried out when importing the data.

Boundary(B.):

The program removes boundary points.

5deg. & B.,10deg. & B., 15deg. & B., 20deg. & B.:

The program removes boundary points, and also removes polygons within the
specified

angular range (5°, 10 °, 15°, or 20 °) to the view vector.

Filter

None: The program does not perform filtering when importing the data.

Noise Filter (N.F.): When importing the data, the points that appear to be noise will be corrected

according to other data.

High Quality (H.Q.): The program filters out unreliable data.
H.Q & N.F.:

Applies both noise filter and high quality filter.

n

Deleting the Selected File ([Delete] button)

The [Delete] button is used to delete the selected file from the memory card.

Operating Procedure

Before starting the following procedure, make sure that the [File-Import-Digitizer-PC Card] dialog box is
displayed.

1

From the file list, select the name of the

file you want to delete.

2

Click the [Delete] button.

A message dialog box will appear.

3

Click the [Delete] button.

The file will be deleted.