5E. WATER FLOW THROUGH THE SOFTENER VALVE

FAST RINSE CYCLE

During FAST RINSE, the rotor & disc is positioned so water flow enters the resin tank

through the top distributor, and exits through the bottom distributor, to the drain.
The solid state timer again energizes the motor to return the valve to service, and as the

valve rotates, the position switch lever drops to open the circuit. The valve remains posiĆ

tioned in service until the timer initiates the next regeneration.