Maintenance, Handset - cleaning – Kohler Thermostatic Electric Shower User Manual

Page 23

Advertising
background image

3

Appliance fails

to produce hot

water when set

on Medium/

High Heater

Setting.

ON

II/III

Heater Tank failure.

Contact local water

company.

Replace.

Supply pressure below

0. bar.

Contact local water company.

Check mains water static

pressure.

Any

ON

ON

II/III

ON

II/III

Possible failure of the

Microswitch or thermal

switch.

Use a suitable continuity

device to check the continuity

of the Microswitch or Heater

Tank and replace parts as

necessary.

Water will not

turn off.

Power

Light

Heater

Setting

Low/Medium/

High

Probable Cause

Possible Remedy

Symptom

No change in

temperature

between Low/

Medium/High

setting.

ON

Any

ON

Any

Insufficient mains water

pressure.

Contact local water company.

Possible failure of Flow

Valve, Microswitch, or

Heater Tank.

Use a suitable continuity

device to check the continuity

of the Microswitch or Heater

Tank and replace parts

as necessary.

ON

Any

Inlet Valve, Solenoid, or

Start/Stop switch faulty.

Replace as necessary.

Maintenance

Handset - Cleaning

Clean with mild washing up detergent or

soap solution. Wipe dry with a soft cloth.

Poor shower performance can be

avoided by cleaning the spray plate.

Use thumb or soft cloth to wipe rubber

nozzles. The handset must be descaled

regularly.

Insufficient Water supply.

Advertising