Adjustments – Kohler Coralais rite-temp bath and shower faucet 114522-2-CE User Manual

Page 10

Advertising
background image

114552Ć2Ć

CE

Kohler Co., Kohler, WI

10

ADJUSTMENTS

8.

MAXIMUM WATER

TEMPERATURE ADJUSTMENT

Remove the handle and face plate

from the valve, if installed.

Turn the valve stem fully

clockwise to get maximum hot

water flow.

To adjust the maximum

temperature, slide the stem

OĆring out of groove and part way

up valve stem. Move the upper

limit stop ring part way up the

valve stem. Rotate the valve stem

until the desired maximum water

temperature is reached. Rotate

lower limit stop ring until it

contacts the tab. Slide the upper

limit stop down the valve stem to

engage the lower limit stop. Slide

the OĆring into the valve stem

groove.

Rotate the valve stem

counterclockwise to shut the

water off. Reinstall the handle

and face plate.

Lower Limit

Stop

Tab

Groove

Valve

Stem

OĆRing

Upper Limit

Stop

Advertising