Installation checkout, Install wall – Kohler Coralais rite-temp bath and shower faucet 114522-2-CE User Manual

Page 6

Advertising
background image

114552Ć2Ć

CE

Kohler Co., Kohler, WI

6

BackĆtoĆBack Installation:

Never install a valve body upside

down. If two valves are installed

in a backĆtoĆback configuration,

install both as previously

instructed. The supplies to one of

the valves will be reversed.

To correct the valve control on

the reversed valve, remove the

plaster guard, cap assembly and

collar. Rotate the cap assembly

and collar 180

°

(tab on bottom),

reassemble and tighten the

screws.

Reinstall the plaster guard.

Cap

Assembly

Cold

Supply

Screws

Hot

Supply

Tab

Valve

Body

180

_

Collar

Plaster

Guard

INSTALLATION CHECKOUT

4.

Install caps to the temporary bath

and shower nipples.

Turn on the hot and cold water

supplies and check the new

installation for leaks.

Remove the caps from the

temporary nipples.

Remove the plaster guard.

Turn the valve stem to the On"

position and cycle the control

through its operating range.

Turn the valve off.
If the valve has stops, rotate

both stop adjustments fully

clockwise.
Turn the valve on and verify

that water does not run.
Turn the valve off and rotate

both stop adjustments fully

counterclockwise.
Reinstall the plaster guard.

INSTALL WALL

5.

Thick Wall Installation (Tile,

Plaster, Marble, etc.): Provide

a 5Ć9/16" (141.1cm) diameter hole

in the rough wall material. The

flat front surface of the plaster

guard must be flush with the

finished wall.

Complete the finished wall.

Do not remove the plaster guard

until instructed.

2Ć3/4" (7cm)-4" (10.2cm)

RoughĆIn Depth

Finished Wall

Plaster

Guard

UP

HOT

5Ć9/16"

(141.1cm) D.

Advertising