26 PREPARATION

A. Wiring Clamp
B. 1 P Connector (Negative Lead)
C. 2 P Connector
D. 3 P Connector
E. Battery Holder Nuts
F. Battery Holder
G. Battery
H. 6 P Connector (Rear Harness)
I. 4 P Connector (Diagnosis)
J. Plastic Clamp
K. 15 A Fuse Holder
L. Harness (Fuel Pump)
M. Harness (Fuel Gauge)

Remove the 15 A fuse holder from the battery
holder, then remove the battery holder.

A. Battery Holder
B. 15 A Fuse Holder
C. Projection
D. Screwdriver

Take the battery out of the battery case.

Clean the terminals.

Battery Specifications

Make

Furukawa

Battery Type

FTZ16-BS

Battery Capacity

12 V 18 Ah

Electrolyte Capacity

0.82 L

Battery/Electrolyte Set P/No.

26012-1371

Battery Activation
Filling the Battery with Electrolyte

CAUTION

Do not remove the aluminum sealing
sheet [A] from the filler ports [B] until
just prior to use. Be sure to use the ded-
icated electrolyte container for correct
electrolyte volume.

Place the battery on a level surface.

Check to see that the sealing sheet [A] has no
peeling, tears, or holes in it.

Remove the sealing sheet [A].

NOTE

ż

The battery is vacuum sealed. If the sealing
sheet has leaked air into the battery, it may
require a longer initial charge.

Remove the electrolyte container from the
vinyl bag.

Detach the strip of caps [A] from the container
and set aside, these will be used later to seal
the battery.

NOTE

ż

Do not pierce or otherwise open the sealed
cells [B] of the electrolyte container. Do not
attempt to separate individual cells.

Advertising